CDSCO MD-7 Endorsement for Medical Devices: A Practical Guide for Manufacturers
Youâve got your Class C or Class D manufacturing licence. Your team has just finished a new device, or a new size of an existing one. Can you start selling it? Not yet. In India, every device you manufacture must be listed on your licence, and thatâs where the MD-7 endorsement comes in. This guide explains what CDSCO MD-7 endorsement is, when you need it, what to submit, and how to avoid the delays that catch most manufacturers off guard.
Schedule a Call Back
2,100+ CDSCO medical device assignments since 2018
Clients include Endolite India, Mankind Pharma, Ossur India, ADK Health Care, Credence Prosthetic India, V2U Physio Asia, International Electro Medical Company, Radimage Healthcare India, Istok New Hearing AID, Simpladent Implant Solutions, Starkey Laboratories India, Gentec Medical (12 of 1,100+ served since 2018).
A few more clients we've served in this industryHide the list
- Pharma and healthcare
- Endolite India ¡ Mankind Pharma ¡ Ossur India ¡ ADK Health Care ¡ Credence Prosthetic India ¡ V2U Physio Asia ¡ International Electro Medical Company ¡ Radimage Healthcare India ¡ Istok New Hearing AID ¡ Simpladent Implant Solutions ¡ Starkey Laboratories India ¡ Gentec Medical ¡ Cureesse Pharma ¡ Hygiene Medicus ¡ Nexus Surgical and Medicare
- More clients
- Meditronix Corporation ¡ Nilkamal ¡ Haesi GHL ¡ GHL ¡ Servotech Power Systems ¡ Elektrocraft India ¡ Happy Medicare ¡ Anantaa Gsk Innovations ¡ Cogmac Technologies ¡ Aficionados Tech ¡ Superceuticals ¡ Truevis Technologies ¡ 1008 Digital Health ¡ BDS Services ¡ Evoq Imaging Technologies ¡ Premier Medical Systems and Devices ¡ Riransa ¡ Vitrag Infra Projects ¡ Insta Biotech ¡ Digital Acoustics ¡ Artificial Learning Systems India ¡ Nfilade Security Solutions ¡ Humors Tech ¡ K2O Consulting
What is Form MD-7?
Form MD-7 is the application form for a licence to manufacture Class C or Class D medical devices for sale or distribution in India. It is prescribed under the Medical Devices Rules, 2017 (MDR 2017) and filed with the Central Licensing Authority, which is the Drugs Controller General of India (DCGI) at CDSCO.
When the application is approved, CDSCO issues the licence in Form MD-9. So, in short:
- MD-7 is the application.
- MD-9 is the licence you receive.
Class C (moderate-high risk) and Class D (high risk) devices include products such as many implants, ventilators, haemodialysis equipment, and certain in-vitro diagnostic kits. The exact class of your device depends on CDSCOâs risk classification lists and the classification rules in the First Schedule of MDR 2017.
What does MD-7 endorsement mean?
An MD-9 licence doesnât cover every device your company might ever make. It covers the specific devices, models and variants approved and listed in it.
âMD-7 endorsementâ is the term the industry commonly uses for adding new devices to an existing Class C or Class D manufacturing licence. You file the request through the MD-7 route on CDSCOâs online medical device portal, and once approved, the new devices are endorsed (added) to your MD-9 licence.
Think of your licence as a guest list. The venue (your manufacturing site) is already approved. Endorsement adds new names to the list.
When do you need an endorsement?
Youâll usually need one when you want to:
- Manufacture a new medical device at an already licensed site
- Add new models, sizes or variants that arenât covered by your current licence
- Add a device of a different generic type or intended use
Some changes to devices already on your licence (such as changes to material, design or intended use) may count as âmajor changesâ that need CDSCOâs prior approval rather than a fresh endorsement. If youâre unsure which route applies, check with CDSCO or a regulatory consultant before filing. Filing the wrong application is one of the most common causes of delay.
Who needs MD-7 endorsement?
- Indian manufacturers holding an MD-9 licence who are expanding their product range
- Contract manufacturers adding devices for a new brand-owner client
- Companies whose devices moved into Class C or D licensing as CDSCOâs phased regulation of all medical devices came into force
If your device is Class A or Class B, MD-7 isnât for you. Those devices follow the Form MD-3 route, handled by the State Licensing Authority, and the licence is issued in Form MD-5.
MD-3 vs MD-7: Quick comparison
| Point | Form MD-3 | Form MD-7 |
| Device class | Class A and Class B | Class C and Class D |
| Licensing authority | State Licensing Authority | Central Licensing Authority (CDSCO) |
| Licence issued in | Form MD-5 | Form MD-9 |
| Audit or inspection | By a notified body (or the state authority) | By CDSCOâs inspection team, with experts where needed |
| Risk level | Low to low-moderate | Moderate-high to high |
Documents required for MD-7 endorsement
The good news is that you donât start from zero. Many site-level documents are already on CDSCOâs file from your original licence. The focus of an endorsement is the new device.
Usually already on file (update only if changed)
- Plant Master File for the licensed site
- Constitution details of the firm
- Quality Management System records aligned with the Fifth Schedule of MDR 2017 (based on ISO 13485)
- Details of competent technical staff
Needed for each new device
- Device Master File in the format of MDR 2017, covering device description, design, materials, manufacturing process, labelling, and risk management
- Essential principles checklist showing how the device meets safety and performance requirements
- Test reports from a CDSCO-recognised or NABL-accredited laboratory, where applicable
- Labels and instructions for use that meet the labelling requirements of MDR 2017
- Clinical evidence, especially for devices that have no predicate device in India; these may need a clinical investigation approval first
- Proof of fee payment for each distinct device
- Undertaking that the information submitted is true and complete
CDSCO can ask for more based on the device. Always check the latest checklist on the CDSCO website before you file.
CDSCO MD-7 Endorsement Fees
Fees are set in the Second Schedule of MDR 2017. At the time of writing, the commonly cited government fees for a Class C or Class D manufacturing licence are:
| Fee head | Amount |
| Per manufacturing site | âš50,000 |
| Per distinct medical device | âš5,000 |
For an endorsement on an already licensed site, the per-device fee is the main cost. Fees can be revised by notification, so confirm the current amounts on the CDSCO portal before paying. Professional and testing charges are separate.
Step-by-step MD-7 endorsement process
- Confirm the device class. Check the CDSCO classification list for your device. A wrong class means the wrong form.
- Check whether itâs an endorsement or a change. Is it a new device or a change to one already on your licence? The route differs.
- Prepare the Device Master File. This is the heart of the application. Most queries come from gaps here.
- Get testing done. Arrange test reports from a recognised laboratory. If you need samples made for testing first, a test licence (Form MD-12/MD-13) may be required.
- File online. Log in to CDSCOâs online system for medical devices, select the relevant application, upload documents, and pay the fee.
- Respond to queries. CDSCO reviewers may raise queries. Reply clearly and on time.
- Inspection, if required. CDSCO may inspect the site, especially if the new device needs different processes or equipment.
- Receive the endorsed licence. Once approved, the new device appears on your MD-9 licence. Only then can you manufacture it for sale.
How long does it take?
MDR 2017 sets time limits for CDSCOâs inspection and decision. In practice, the total time depends on how complete your file is, how many queries are raised, and whether an inspection is needed. A clean, complete Device Master File is the single biggest factor you control.
We avoid quoting a fixed number of days here because real timelines vary from case to case. Corpseed can give you a realistic estimate once we review your device and documents.
Validity of the licence
Under MDR 2017, an MD-9 licence stays valid unless itâs suspended or cancelled, provided you pay the licence retention fee every five years. Endorsed devices follow the validity of the main licence.
Common mistakes that delay approval
- Filing under the wrong class. A Class B device filed as Class C (or the reverse) gets sent back.
- Generic Device Master Files. Copy-paste files that donât match the actual device draw queries.
- Missing variant details. If a size or model isnât named, it isnât covered.
- Labels that donât meet MDR 2017. Missing licence number, manufacturing date or batch details are frequent issues.
- Ignoring clinical evidence needs. Novel devices without a predicate often need clinical data.
- Selling before approval. Manufacturing a device for sale before itâs endorsed can lead to regulatory action.
How Corpseed helps with MD-7 endorsement
Corpseedâs regulatory team works with medical device manufacturers on CDSCO licensing from start to finish:
- Confirming device classification and the right application route
- Preparing and reviewing the Device Master File and Plant Master File
- Coordinating test reports and labelling checks
- Filing on the CDSCO portal and handling queries
- Preparing your site for inspection
Whether youâre adding one new model or a whole product line, we help you file it right the first time.
Ready to add new devices to your CDSCO licence? Talk to a Corpseed regulatory expert for a free consultation and a document checklist tailored to your device.
Schedule a Call Back
About the Author

Shamshad Alam
Head - Digital MarketingExperienced Digital Marketer with a demonstrated history of working in the Internet industry. He likes to write about the latest technology trends, Skilled in Digital Marketing likes. Search Engine Optimization, SMO, SEM, PPC, Content Writing, and, Designing, etc.
Related articles

Medical Devices PLI Scheme 2026: New Applications, Eligibility, Incentives & Benefits
2026-11-12

CDSCO Export NOC for r-DNA Products: Who Needs It?
2026-10-21

CDSCO Registration: A Simple Guide to Getting Your License in India 2026
2026-10-21

Importing Cosmetic Gift Sets into India? CDSCO, LMPC & Labelling Checklist
2026-10-14

CDSCO Medical Device Registration Consultant
2026-09-23

CDSCO Registration for Lab Equipment and Diagnostic Devices
2026-09-22